HPE ProLiant Server CLI Commands
# rpm -ivh hpacucli-x.x-x.xxxx.rpm
cpqacuxe -R
cpqacuxe -stop
Commands Keyword | abbreviation |
---|---|
controller | ctrl |
logicaldrive | ld |
Commands | Note |
---|---|
hpacucli | To start the HP ACU-CLI application |
help | a list of supported commands |
exit | close the console. |
Linux
# hpacucli HP Array Configuration Utility CLI Version x.x.x Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. =>
Windows
C:\Program Files\Compaq\Hpacucli\Bin\hpacucli.exe
Commands | Note |
---|---|
controller all show | Show HBA list |
controller all show status | Show HBA list in exact detail |
controller slot=0 show | Show HBA in exact detail |
controller slot=0 physicaldrive all show | show physical drive status |
controller slot=0 array all show | show array status |
controller slot=0 logicaldrive all show | show logical drive status |
Commands | Note |
---|---|
rescan | |
controller slot=0 create type=logicaldrive drives=0:0,0:1 raid=1 size=max | |
controller slot=0 array A create type=logicaldrive | |
controller slot=0 array A add spares=0:2 |
Commands | Note |
---|---|
hpacucli help | |
hpacucli ctrl all show config | |
hpacucli ctrl all show status | |
hpacucli ctrl slot=0 pd all show | Show physicaldrive |
hpacucli controller slot=0 show ssdinfo | |
hpacucli controller slot=0 show ssdinfo detail |
Commands | Note |
---|---|
hpacucli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 | Create logicaldrive |
# hpacucli ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: 500143800XXXXXXX) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) #
# hpacucli ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 50014380069D34C0 RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 2.74 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Stripe Size: 128 KB Status: OK Array Accelerator: Disabled Unique Identifier: 600508B1001030363944463232300D00 Disk Name: /dev/cciss/c0d0 Mount Points: / 132.8 GB Logical Drive Label: A00010B650014380069DF220D972 Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDC Serial Number: 3SD218Y300009019V2U6 Model: HP DG0146FAMWL PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDC Serial Number: 3SD20BMK00009019PGP2 Model: HP DG0146FAMWL PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown
# hpacucli ctrl all show status Smart Array P400i in Slot 0 Controller Status: OK Cache Status: OK #