HPE ProLiant Server CLI Commands
# rpm -ivh hpacucli-x.x-x.xxxx.rpm
cpqacuxe -R
cpqacuxe -stop
| Commands Keyword | abbreviation |
|---|---|
| controller | ctrl |
| logicaldrive | ld |
| Commands | Note |
|---|---|
| hpacucli | To start the HP ACU-CLI application |
| help | a list of supported commands |
| exit | close the console. |
Linux
# hpacucli HP Array Configuration Utility CLI Version x.x.x Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. =>
Windows
C:\Program Files\Compaq\Hpacucli\Bin\hpacucli.exe
| Commands | Note |
|---|---|
| controller all show | Show HBA list |
| controller all show status | Show HBA list in exact detail |
| controller slot=0 show | Show HBA in exact detail |
| controller slot=0 physicaldrive all show | show physical drive status |
| controller slot=0 array all show | show array status |
| controller slot=0 logicaldrive all show | show logical drive status |
| Commands | Note |
|---|---|
| rescan | |
| controller slot=0 create type=logicaldrive drives=0:0,0:1 raid=1 size=max | |
| controller slot=0 array A create type=logicaldrive | |
| controller slot=0 array A add spares=0:2 |
| Commands | Note |
|---|---|
| hpacucli help | |
| hpacucli ctrl all show config | |
| hpacucli ctrl all show status | |
| hpacucli ctrl slot=0 pd all show | Show physicaldrive |
| hpacucli controller slot=0 show ssdinfo | |
| hpacucli controller slot=0 show ssdinfo detail |
| Commands | Note |
|---|---|
| hpacucli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 | Create logicaldrive |
# hpacucli ctrl all show config
Smart Array P410i in Slot 0 (Embedded) (sn: 500143800XXXXXXX)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (136.7 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
#
# hpacucli ctrl all show config detail
Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 50014380069D34C0
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev C
Firmware Version: 2.74
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: False
Drive Write Cache: Disabled
SATA NCQ Supported: True
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Logical Drive: 1
Size: 136.7 GB
Fault Tolerance: RAID 1
Heads: 255
Sectors Per Track: 32
Cylinders: 35132
Stripe Size: 128 KB
Status: OK
Array Accelerator: Disabled
Unique Identifier: 600508B1001030363944463232300D00
Disk Name: /dev/cciss/c0d0
Mount Points: / 132.8 GB
Logical Drive Label: A00010B650014380069DF220D972
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
Mirror Group 1:
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDC
Serial Number: 3SD218Y300009019V2U6
Model: HP DG0146FAMWL
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDC
Serial Number: 3SD20BMK00009019PGP2
Model: HP DG0146FAMWL
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
# hpacucli ctrl all show status Smart Array P400i in Slot 0 Controller Status: OK Cache Status: OK #