NetApp Data ONTAP 7-Mode CLI Commands [Old Device]
| Operation | Command | Complement |
|---|---|---|
| Displays Data ONTAP version. | version version -b ← include firmware | |
| Displays detailed information about each I/O device. For SCSI or Fibre Channel host adapters | sysconfig -v | Including Memory |
| Check Hardware Checks that expansion cards are in the appropriate slots. | sysconfig -c | |
| Displays very detailed information about each I/O device. This is more verbose than the output produced by the -v option. | sysconfig -a | |
| Displays RAID configuration information. | sysconfig -r | If HDD failed, you can see “prefail” |
| Displays vital product information for each disk. | sysconfig -d | |
| Displays a listing of the spare disks on the node. | aggr status -s |
| Operation | Command | Complement |
|---|---|---|
| halt | halt -t 0 -f | -f : Not fail |
| priv set diag disk unfail -s 0a.26 | ||
| pdisk zero spares |
> version NetApp Release 8.1.1 7-Mode: Mon Jul 30 12:49:46 PDT 2012
> version -b /cfcard/x86_64/freebsd/image1/kernel: OS 8.1.1 /cfcard/x86_64/freebsd/image2/kernel: OS 8.1.1 /cfcard/x86_64/diag/diag.krn: 5.7 /cfcard/x86_64/firmware/excelsio/firmware.img: Firmware 1.9.0 /cfcard/x86_64/firmware/DrWho/firmware.img: Firmware 2.5.0 /cfcard/x86_64/firmware/SB_XV/firmware.img: Firmware 4.4.0 /cfcard/x86_64/firmware/SB_XVI/firmware.img: Firmware 5.1.1 /cfcard/x86_64/firmware/SB_XVIII/firmware.img: Firmware 7.1.2 /cfcard/x86_64/firmware/SB_XIX/firmware.img: Firmware 8.1.0 /cfcard/common/firmware/zdi/zdi_fw.zpk: Flash Cache Firmware 2.2 (Build 0x201012201350) /cfcard/common/firmware/zdi/zdi_fw.zpk: PAM II Firmware 1.10 (Build 0x201012200653) /cfcard/common/firmware/zdi/zdi_fw.zpk: X1936A FPGA Configuration PROM 1.0 (Build 0x200706131558)
> sysconfig -a
NetApp Release 8.1.2P1 7-Mode: Mon Jan 7 15:55:05 PST 2013
System ID: 1901000XXX (testnetapp1); partner ID: 19010XXXX2 (test-netapp2)
System Serial Number: 700001456XXX (infra-eaa-netapp1)
System Rev: D1
System Storage Configuration: Single-Path HA
System ACP Connectivity: Partial Connectivity
slot 0: System Board 1.7 GHz (System Board XIX D1)
Model Name: FAS2240-4
Part Number: 111-00XXX
Revision: D1
Serial Number: 941719XXXX
BIOS version: 8.1.0
Loader version: 4.1
Processors: 4
Processor ID: 0x106e4
Microcode Version: 0xffff0002
Processor type: Intel(R) Xeon(R) CPU C3528 @ 1.73GHz
Memory Size: 6144 MB
Memory Attributes: Hoisting
Normal ECC
NVMEM Size: 768 MB of Main Memory Used
CMOS RAM Status: OK
Controller: A
Service Processor Status: Online
Firmware Version: 2.1.2
Mgmt MAC Address: 00:A0:98:42:XX:XX
Ethernet Link: up, 100Mb, half duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: 192.168.0.10
Netmask: 255.255.255.0
Gateway: 192.168.0.1
IPv6 configuration: Disabled
slot 0: Internal 10/100 Ethernet Controller
e0M MAC Address: 00:a0:98:42:xx:xx (auto-100tx-fd-up)
e0P MAC Address: 00:a0:98:42:xx:xx (auto-100tx-fd-up)
Device Type: Rev 0
memory mapped I/O base 0x00000000dfa00000, size 0x20000
I/O base 0x0000000000003000, size 0x20
memory mapped I/O base 0x00000000dfa20000, size 0x4000
memory mapped I/O base 0x00000000dfb20000, size 0x20000
I/O base 0x0000000000004000, size 0x20
memory mapped I/O base 0x00000000dfb00000, size 0x4000
slot 0: Quad Gigabit Ethernet Controller 82580
e0a MAC Address: 00:a0:98:42:70:d2 (auto-1000t-fd-up)
e0b MAC Address: 00:a0:98:42:70:d3 (auto-1000t-fd-up)
e0c MAC Address: 00:a0:98:42:70:d4 (auto-1000t-fd-up)
e0d MAC Address: 00:a0:98:42:70:d5 (auto-1000t-fd-up)
Device Type: 150E
memory mapped I/O base 0x00000000df700000, size 0x80000
I/O base 0x0000000000002040, size 0x20
memory mapped I/O base 0x00000000df808000, size 0x4000
memory mapped I/O base 0x00000000df780000, size 0x80000
I/O base 0x0000000000002060, size 0x20
memory mapped I/O base 0x00000000df80c000, size 0x4000
memory mapped I/O base 0x00000000df600000, size 0x80000
I/O base 0x0000000000002000, size 0x20
memory mapped I/O base 0x00000000df800000, size 0x4000
memory mapped I/O base 0x00000000df680000, size 0x80000
I/O base 0x0000000000002020, size 0x20
memory mapped I/O base 0x00000000df804000, size 0x4000
slot 0: Interconnect HBA: Mellanox IB MT25204
GUID: 0x100000a0984270d2 LID: 0x4 Remote LID: 0x5
Firmware rev: 1.0.800
Hardware rev: 160
Command rev: 1
Cluster Interconnect Port: 4x
memory mapped I/O base 0xdf400000, size 0x100000
prefetchable memory base 0xde800000, size 0x800000
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
Firmware rev: 01.11.00.00
Base WWN: 5:00a098:001b2b0:f0
Phy State: [0] Enabled, 6.0 Gb/s
[1] Enabled, 6.0 Gb/s
[2] Enabled, 6.0 Gb/s
[3] Enabled, 6.0 Gb/s
00.0 : NETAPP X306_HMARK02TSSM NA04 1695.4GB 512B/sect (YGJVPPYB)
00.1 : NETAPP X306_HMARK02TSSM NA04 1695.4GB 512B/sect (YGJVPY2B)
00.2 : NETAPP X306_HMARK02TSSM NA04 1695.4GB 512B/sect (YFJZG94A)
00.3 : NETAPP X306_HMARK02TSSM NA04 1695.4GB 512B/sect (YGJVNN5B)
00.4 : NETAPP X306_HMARK02TSSM NA04 1695.4GB 512B/sect (YFJZH8VA)
(abbr)
> sysconfig -r
Aggregate aggr2 (online, raid_dp) (block checksums)
Plex /aggr2/plex0 (online, normal, active, pool0)
RAID group /aggr2/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.7 0a 0 7 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
parity 0a.00.8 0a 0 8 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.9 0a 0 9 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.10 0a 0 10 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.11 0a 0 11 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.12 0a 0 12 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.13 0a 0 13 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.14 0a 0 14 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.15 0a 0 15 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.16 0a 0 16 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.17 0a 0 17 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.18 0a 0 18 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.19 0a 0 19 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.20 0a 0 20 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.21 0a 0 21 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
Aggregate aggr0 (online, raid_dp) (block checksums)
Plex /aggr0/plex0 (online, normal, active, pool0)
RAID group /aggr0/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.1 0a 0 1 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
parity 0a.00.3 0a 0 3 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
data 0a.00.5 0a 0 5 SA:A 0 BSAS 7200 1695466/3472315904 1695759/3472914816
Aggregate aggr1 (online, raid_dp) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.10.0 0a 10 0 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
(abbr)